Dynamic Load Management protects the main fuse of a property from overload by monitoring the total load being drawn by the property and adjusting the EV charger output accordingly.
For example:
- Main house fuse = 60 amps
- EV charger max power = 32 amps
- Power shower = 40 amp
If the EV was charging and somebody decided to have a shower this could blow the main house fuse - 32 + 40 = 72 amps (fuse exceeded by 12 amps). In this case the load management device will tell the charger to reduce its charge rate to <20 amps until the shower is turned off, thus protecting the main fuse.
This feature is only available as an option with the installation of a separate CT Clamp which is designed for installation inside the main consumer unit or around the tails from the main fuse.
Our CT clamp/Dynamic Load Management Kit part numbers are:
- EVA120CT1 (for EVS and EVT models)
- SYNC-LMK (for EVCP models)
Click here to view our range of accessories